Categoria: Scientific Paper

Combined antibiotic therapy spacers either commercial or handmade are superior to monotherapy – a microbiological analysis at the second stage of revision

  • Data di pubblicazione: 26/03/24
  • Share on

Categorie

Contattaci

Vuoi metterti in contatto diretto con noi?

Infected arthroplasty: 2-stage revision with mono or multiple AB spacers

Authors

Carvalho AD, Ribau A,
Soares D, Santos AC,
Abreu M, Sousa R

Institute

Department of Orthopaedics
Microbiology, Infectious Disease Porto University Hospital,
Porto (Portugal)

Journal

Journal of Bone and Joint Infection

Take Home message

  • Multiple-AB spacer is better than single AB spacer;
  • GV preformed spacers performs better than multiple AB hand-made spacer.
Study details   Score Range
Subject Clinical - -
Type Retrospective study 1 1 - 5
Journal J Bone Joint Inf 2 1 - 3

Summary

58 patients with a hip or knee arthroplasty received a Tecres preformed spacer (G or GV) or a hand-made spacer with G, V and Meropenem (M). Multiple AB spacers are more effective than single AB spacer: fewer positive cultures (failure indication) at 2nd stage

Sample characteristics

58 patients (26M, 32F) with a mean age of 67 Y (39 - 85)
Joint: 22 hips + 36 knees
Spacer type: 14 single AB + 44 multiple AB (24 GV + 20 GVM)
Pathogens: difficult-to-treat 15/58 (25.9%)
Previous surgical treatment for PJI: 28/58 (48.3%)
ASA classification ≥ 3: 29/58; BMI ≥ 30: 20/58; Diabetes: 26/58

Spacer implantation (range)

4,6 months (2 - 6)

FU (range)

46 months

Results

Infection eradication
  • No signs of recurrence in 49/58 (84.5%). Failure in 9/58 (15.5%)
  • G failure: 4/14 (28.6%); GV failure: 2/24 (8.3%); GVM failure 3/20 (15%)

Positive cultures analysis
  • Positive cultures at 2nd stage: 11/58 (19.0%)
  • Failure: 7/11 (63.6%) with p.ve cultures; 2/47 (4.3%) with n.ve cultures
Multivariate analysis
  • Single AB spacer is a significant independent prognostic factor for p.ve cultures at 2nd stage

Complications
  • 3 hip dislocations; 2 fractures

Key points

  • Multiple AB spacer is more effective in PJI than single AB spacer
  • Preformed GV spacers produce half the failures of handmade GVM spacers
  • 2-stage revision is a viable treatment option for patients with complicated surgical histories or with difficult to treat infections

Score

Study value Description
* Retrospective study
* * Retrospective comparative
Retrospective Register study
* * * Prospective study
Systematic review
Meta-analysis
* * * * Randomized controlled trial (RCT)
* * * * * Randomized controlled trial (RCT)
Journal value Description
* Low impact factor (<1.500)
* * Medium impact factor (>1.500 – <2.500)
* * * High impact factor (> 2.500)

Attenzione

State per accedere ad un'area riservata SOLO agli operatori del settore medico. Requisiti regolatori e norme mediche possono variare da Stato a Stato, così come le informazioni legali e la protezione dei dati personali. Le informazioni presenti nell'area cui state per accedere potrebbero non essere appropriate all'uso nel vostro Stato. Cliccando su Continua, confermate di essere operatori del settore medico e di aver compreso che lo statuto legale e le politiche di privacy possono essere diverse da quelle del vostro Paese.

Confermi l'iscrizione a questo evento?